Specify TemStock-FR when constructing wall systems, fixtures, cabinets or furniture for industrial or commercial applications where a Class 1 fire rating is desired. It is an excellent substrate for wood veneers, high and low pressure laminates, as well as vinyl overlays, and may be cut, machined or drilled without significant effect on its flame spread rating.
Dimensions
| Thickness (in.) | 3/8 - 1-1/8 |
| Panel Sizes (in.) countertops and shelving available |
Standard 4-foot sizes |
Physical Properties
| Averages1 | 3/8"- < 5/8" | 5/8" - 3/4" | > 3/4" |
|---|---|---|---|
| MOR-Modulus of Rupture (psi) | 1600 | 1400 | 1400 |
| MOE-Modulus of Elasticity (kpsi) | 290 | 270 | 270 |
| IB-Internal Bond (psi) | 80 | 70 | 55 |
| Face Screw Holding Capacity (lbs) | 225 | 225 | 225 |
| Edge Screw Holding Capacity (lbs) | NA | 160 | 160 |
| Formaldehyde Emission (ppm)2 | 0.09 | 0.09 | 0.09 |
| Flame Spread3 | See Note 3 | See Note 3 | See Note 3 |
| Smoke Developed3 | See Note 3 | See Note 3 | See Note 3 |
|
1. One-panel minimum average (ASTM D1037 / ANSI A208.1-2009) 2. Non-averaged maximum test value 3. Underwriters Laboratories, Inc. Classified Wood Particleboard: Surface Burning Characteristics. UL 723-Class 1 or ASTM E-84 Class A. |
|||
Tolerances
| Length & Width Tolerance | ± 1/16" |
| Squareness Tolerance | ≤ 1/8" |
| Straightness Tolerance | ± 1/64" / 2ft. |
| Thickness Tolerance (Within Panel Average) |
± 0.004" |
| Thickness Tolerance (Panel to Panel Average) |
± 0.004" |
Environmental Credits
| LEED | Credits | Description |
|---|---|---|
| Recycled Content | MR credit 4 | Awards 1 or 2 points for using products with recycled content that constitute at least 10% or 20%, based on cost, of the total value of project materials. |
| Locally Produced Materials | MR credit 5 | Awards 1 or 2 points for using materials on a project that are extracted and manufactured within 500 miles that constitute at least 10% or 20%, based on cost, of the total value of project materials. |
| NAHB | Credits | Description |
|---|---|---|
| Pre-Consumer Recycled Content | 604.1(2) | Use recycled content products in major areas such as walls, floors, insulation and roofing. |
| FSC® Certification | 606.2(3) | Wood or wood-based products available that are certified by Forest Stewardship Council™. |
| Other Certification | 606.2(6) | Wood-based components certified in accordance to CPA ECC 4-11. |
| Low Formaldehyde/VOC Emissions | 901.4(a) | In compliance with ANSI A208.1. |
| Low Formaldehyde/VOC Emissions | 901.4(c) | In compliance with CPA ECC 4-11. |
| CARB | Credits | Description |
|---|---|---|
| California Air Resource Board | C.A.R.B. | Approved NAF exemption, exceeding requirements of CARB, Phase 2. |
ECC Certification
TemStock particleboard products produced in Temple-Inland’s Monroeville, Alabama, Hope, Arkansas, Thomson, Georgia, and Diboll, Texas, facilities have been awarded the Composite Panel Association (CPA) Eco-Certified Composite (ECC) grademark, signifying compliance with the highest industry measure of environmental responsibility.
Read more about ECC certification criteria which includes standards for formaldehyde emissions, carbon storage, localized use of renewable resources, recycled and/or recovered fiber, sustainability and responsible wood sourcing.
FSC Certification
Particleboard produced at Temple-Inland's Monroeville, Alabama, Hope, Arkansas, Thomson, Georgia, and Diboll, Texas, facilities that is certified to conform to the requirements of Forest Stewardship Council™ standards for Chain of Custody, Controlled Wood and Reclaimed Material manufacturing is available by special order.

Formaldehyde Emissions
Large chamber air sample testing of Temple-Inland TemStock products has been conducted per ASTM E1333-96 (2002) to verify their conformance to California Air Resources Board (CARB) Phase 2 formaldehyde emission standards as well as the requirements of ANSI A208.1 Table B and HUD DFR Part 3280.
Warning
This particleboard contains low fuming urea formaldehyde resin and may release formaldehyde vapors in low concentrations. Formaldehyde vapors can be potentially irritating to the eyes and upper respiratory system. Should irritation develop, consult your physician.